logo
  • English
Home ProductsPTFE Immersion Heaters

Fluoropolymer PTFE Single Element Heater Open Fluid Path Immersion Heater HXO Style

Certification
China Surplus Industrial Technology Limited certification
China Surplus Industrial Technology Limited certification
I'm Online Chat Now

Fluoropolymer PTFE Single Element Heater Open Fluid Path Immersion Heater HXO Style

Fluoropolymer PTFE Single Element Heater Open Fluid Path Immersion Heater HXO Style
Fluoropolymer PTFE Single Element Heater Open Fluid Path Immersion Heater HXO Style

Large Image :  Fluoropolymer PTFE Single Element Heater Open Fluid Path Immersion Heater HXO Style

Product Details:
Place of Origin: China
Brand Name: Surplus
Certification: ISO9001
Model Number: PTFE immersion Heater 06
Payment & Shipping Terms:
Minimum Order Quantity: 1 PCS
Price: Contact Us
Packaging Details: Wooden Case or Carton Box
Delivery Time: 10-15 working days
Payment Terms: TT, Paypal, Western Union
Supply Ability: 50 PC/Month

Fluoropolymer PTFE Single Element Heater Open Fluid Path Immersion Heater HXO Style

Description
Name: HXO Style Fluoropolymer-PTFE-Single Element Heater Open Fluid Path Single Phase Immersion Heater Supply Voltage (V/Phase):: 110V-480V
Power(KW): 1KW-6KW Type Of Temperature Control: Overheat Protection
Application: Acid Heating And Corrosive Chemical Heating Frame Material: PTFE
Inside Material: SUS Cable Length: 2 Meters/3meters/others
Highlight:

PTFE Single Element Heater

,

Open Fluid Path Immersion Heater

,

Fluoropolymer Single Element Heater

HXO Style Fluoropolymer-PTFE-Single Element Heater Open Fluid Path Single Phase Immersion Heater

PTFE HEATERS:

Specify thermal overload protection desired. Guards are recommended on over the side heaters and required on L-Shaped heaters. Standard guard is polypropylene. Fluoropolymer (PTFE) guards recommended for chromic acid and solutions exceeding 180º F (82ºC).

 

Excellent chemical resistance to aggressive acids.

PTFE Immersion Heater For Corrosive Chemical Heating FEATURES

· PTFE sleeved 304 stainless elements inert to most solutions up to 212°F (100°C).

· Low watt density design 10 watts/square inch (1.5w/cm²).

· Vapor resistant, flame retardant polypropylene terminal enclosure with 3 ft (.9m) flexible PVC liquid tight conduit.

· Grounded internal metal element and built in thermal protector. Replaceable P1 protector standard for solutions up to 180°F(82°C).

· Certification: ISO9001,CE

SPECIFICATIONS

· 500 - 9000 watts

· 120 to 600 volts (600 volts on 4500 watts or lower only)

OPTIONS AVAILABLE (CONSULT FACTORY)

· Resettable thermal protectors

· Polypropylene guards (sold separately)

· Custom configurations and lengths

· Custom wire and conduit lengths

 

Specify thermal overload protection desired. Guards are recommended on over the side heaters and required on L-Shaped heaters.

Standard guard is polypropylene. Fluoropolymer (PTFE) guards recommended for chromic acid and solutions exceeding 180º F (82ºC).

 

 

Others Applications

 

Point Of Use Heating
Point of Use (POU) Heating refers to the energy-efficient heating method of placing a small heater near the processing bath to reduce heat-up wait times.

 

Products For Point Of Use Heating

Applications

  • Semiconductor Wafer Cleaning

  • Etching

  • Inline Chemical Heating

  • Point of Use Heating (POU)

High-Purity PFA Inline Chemical Heater

Fluoropolymer PTFE Single Element Heater Open Fluid Path Immersion Heater HXO Style 0

PTFE Inline Heater

 

Fluoropolymer PTFE Single Element Heater Open Fluid Path Immersion Heater HXO Style 1

Inline Chemical Heater

 

Fluoropolymer PTFE Single Element Heater Open Fluid Path Immersion Heater HXO Style 2

 

RO/DI Water Heating
Deionized water (DI Water) has become a crucial part of many industrial process applications' impurity removal process. Cleaning semiconductors or other ultra-clean end-use devices requires the highest level of purity to reduce product failure.

 

Products For RO/DI Water Heating

 

Applications

  • Semiconductor

  • Flat Panel Display

Heating Systems for Purified, DI Water

Fluoropolymer PTFE Single Element Heater Open Fluid Path Immersion Heater HXO Style 3

PTFE Inline Chemical Heater

Fluoropolymer PTFE Single Element Heater Open Fluid Path Immersion Heater HXO Style 4

 

 

Precious Metal Deposition
Engineered to meet the most stringent requirements, accurate and reliable Heaters in Precious Metals' Deposition reduce materials waste. Low ripple Power Supplies provide clean and smooth direct current (DC), precision results while also saving on materials.

Products For General Metal Finishing

MOTS SINGLE
MOTS Single Heater –
Chemical and Small Immersion Heater: Metal over the side single heater. Single or three phase. 1000-12000 watts, 120-600 volts.

Fluoropolymer PTFE Single Element Heater Open Fluid Path Immersion Heater HXO Style 5

MOTS SINGLE – DAS, PHOSPHATE
MOTS Single DAS Phosphate Heater – Top Portable Electric Immersion Heaters: Phosphate, metal over the side heater. Single or three phase. 1000-10000 watts, 120-600 volts.

Fluoropolymer PTFE Single Element Heater Open Fluid Path Immersion Heater HXO Style 6

MOTS TRIPLE – L SHAPED, DERATED
Derated, low watt density, L-shaped, bottom style metal over the side heater. 1500-18000 watts, 120-480 volts.

Fluoropolymer PTFE Single Element Heater Open Fluid Path Immersion Heater HXO Style 7

MOTS SINGLE – BOTTOM, DERATED
Derated, low watt density, L-shaped, bottom, metal over the side Immersion Heater. Single or Three phase. Three phase. 500-6000 watts, 120-480 volts.

.Fluoropolymer PTFE Single Element Heater Open Fluid Path Immersion Heater HXO Style 8

 

MOTS TRIPLE – L SHAPED
L-shaped, bottom style metal over the side heater. Three phase. Single or three phase. 3000-36000 watts, 200-600 volts.

Fluoropolymer PTFE Single Element Heater Open Fluid Path Immersion Heater HXO Style 9

 

6HS SERIES – TUBULAR
Over the side, 6 element, tubular heater. Three phase. 6000-21000 watts, 208-600 volts.

Fluoropolymer PTFE Single Element Heater Open Fluid Path Immersion Heater HXO Style 10

 

9HX SERIES
Low watt density, 9 element fluoropolymer (PTFE) sleeved 304 stainless elements inert to most solutions. Three phase. 3000-18000 watts, 208-600 volts.
Fluoropolymer PTFE Single Element Heater Open Fluid Path Immersion Heater HXO Style 11
6HX SERIES
Low watt density, 6 element fluoropolymer (PTFE) sleeved 304 stainless elements inert to most solutions. Three phase. 2000-12000 watts, 208-600 volts.
Fluoropolymer PTFE Single Element Heater Open Fluid Path Immersion Heater HXO Style 12

3HXOL SERIES

Low watt density, 3 element, bottom heater. Fluoropolymer (PTFE) sleeved 304 stainless elements inert to most solutions . 3000-18000 watts, 208-480 volts.

Fluoropolymer PTFE Single Element Heater Open Fluid Path Immersion Heater HXO Style 13

Contact Details
Surplus Industrial Technology Limited

Contact Person: Doris Lu

Tel: 13560811662

Send your inquiry directly to us (0 / 3000)