logo
  • English
Home ProductsInline Chemical Heater

Ultrapure PFA Inline Chemical Heater For Aggressive Acids Chemicals

Certification
China Surplus Industrial Technology Limited certification
China Surplus Industrial Technology Limited certification
I'm Online Chat Now

Ultrapure PFA Inline Chemical Heater For Aggressive Acids Chemicals

Ultrapure PFA Inline Chemical Heater For Aggressive Acids Chemicals
Ultrapure PFA Inline Chemical Heater For Aggressive Acids Chemicals Ultrapure PFA Inline Chemical Heater For Aggressive Acids Chemicals

Large Image :  Ultrapure PFA Inline Chemical Heater For Aggressive Acids Chemicals

Product Details:
Place of Origin: China
Brand Name: Surplus
Certification: ISO9001,CE
Model Number: Inline chemical Heater 032
Payment & Shipping Terms:
Minimum Order Quantity: 1 PCS
Price: Negotiable
Packaging Details: Wooden Case or Carton Box
Delivery Time: 10-15 working days
Payment Terms: T/T
Supply Ability: 50 PC/Month

Ultrapure PFA Inline Chemical Heater For Aggressive Acids Chemicals

Description
Name: Ultrapure In-Line Heaters PFA Inline Chemical Heater For Aggressive Acids & Chemicals Voltage: 240V(Customizable),3 Phase
Power: 2kw-18KW Material: Ultrapure PDVF Wetted Surfaces For Optimal Compatibility With Aggressive Chemicals
Heater Applications: Heating Deionized Water, Acids, And Less Aggressive Process Chemistries Use In High-purity Processes Of Semiconductor, Solar, MEMS Manufacturing, And Other Industries Using High-purity Fluids. Market: Semiconductor,Life Sciences
Highlight:

Aggressive Acids Inline Chemical Heater

,

Ultrapure Inline Chemical Heater

,

PFA Inline Chemical Heater

Ultrapure In-Line Heaters PFA Inline Chemical Heater For Aggressive Acids & Chemicals

Overview

Ultrapure In-Line Heaters PFA Inline Chemical Heater For Aggressive Acids & Chemicals are ideal for heating deionized water, acids, and less aggressive process chemistries use in high-purity processes of semiconductor, solar, MEMS manufacturing, and other industries using high-purity fluids.
 
These heaters are designed for recirculation and point-of-use fluid heating applications.
 
Their small footprints allow them to easily integrate into current systems.
 
Available in 1-30 kW and various voltages.

 

We offers a variety of patented and uniquely-engineered ultra-pure precision heaters for heating various chemical and plating solutions, gases, solvents and deionized water.

 

Our award-winning engineers design and manufacture components from PFA, applied to patented PFA heating technology, that achieves a small mass with a large surface area, providing a faster heater response and a longer life at elevated temperatures.

 

Our extremely flexible high-output heating coils are capable of being fashioned into an almost endless variety of shapes and sizes.

 

The resulting heaters outlast competing products of lesser capability and are designed into a wide range of standard and customized products.

Features & Benefits

  • Ultrapure PFA wetted surfaces for optimal compatibility with aggressive chemicals
  • Specialty fittings eliminate wetted O-rings to enhance cleanliness and reduce potential for leaks
  • Fast, powerful temperature response from low-mass heating element with low watt density
  • 160°C maximum temperature
  • Up to 120°C at 60 psi
  • 1-10 kW models available

 

Safety Features

  • Liquid level sensor
  • Ground wire options
  • Over-temperature thermocouple
  • Process thermocouple

Specifications

 
Heater
Patented coil
Wetted Surfaces
PTFE/PFA
Sizes
1 kW to 30 kW (dependent on customer voltage)
Voltages
200 VAC to 480 VAC, 1-ph and 3-ph (dependent on wattage)
Temperature
Ambient to 95º C (203º F)
Temperature Accuracy
± 0.1º C
Flow
0.5 GPM (1.9 LPM) to 32 GPM (122 LPM) (dependent on model)
Pressure
60 PSIG @ 95º C


 
Industries
 

  • Semiconductor Fabrication
  • Solar Cell Manufacturing
  • Flat-Panel Display, LEDs & Electronics
  • Chemicals Manufacturing
  • Industrial Manufacturing

 

Applications

Ultra-High-Purity Heating
Designed with Ultra-High-Purity processes in mind, Surplus delivers clean-room assembled, reliable heating and power solutions to fit specific needs.

 

Products For Ultra-High-Purity Heating

Inline Heater

Ultrapure PFA Inline Chemical Heater For Aggressive Acids Chemicals 0

PFA Inline Heater

 

Ultrapure PFA Inline Chemical Heater For Aggressive Acids Chemicals 1

Inline Chemical Heater

Ultrapure PFA Inline Chemical Heater For Aggressive Acids Chemicals 2

 
 

FAQ

 

What To Do If Your Shipment Is Damaged:

Leave the items, packing material, and carton “as is”. Notify your carrier’s local office and ask for immediate inspection of the carton and its content. After inspection has been made by the carrier, and you have received acknowledgment in writing as to the damage, please contact our Customer Service Department at +86-13560811662 for return authorization. If writing for return authorization, please indicate your purchase order number. We will repair or replace the merchandise depending on the extent of the damage. It is your responsibility to follow the above instructions, or the carrier will not honor any claims for damage. If there are any shortages or questions regarding this shipment, please notify us within ten (10) days.

 

Safety Precautions

Every effort has been made to insure that this unit will run with a minimum of user input or maintenance. However, there are still precautions to be taken whenever operating, performing maintenance, or servicing this unit. This unit makes use of heating elements and electrical components, both of which pose inherent burn, fire, and electrical shock hazards. These hazards can result in injury to personnel, plant, and/or process. Please note the following to aid in the operation of your unit and to decrease risk of the above mentioned hazards.

 

Precautions

 

• Carefully and completely read this and all accompanying literature to verify that you understand the functionality and features of this system. Please become familiar with the integral safeties and controls within this system, and know their function.

 

• Always disconnect electrical power prior to installing, servicing or replacing electric heating elements and/or assemblies.

 

• Electrical termination enclosures should be selected to match the application’s environment and be able to withstand worst-case failures, especially in hazardous locations

 